Purpose

The primary objective of this study is to evaluate the safety and effectiveness of the Surpass™ Evolve Flow Diverter System in the treatment of unruptured, wide-neck intracranial aneurysms measuring ≤ 12 mm and located on the ICA or its branches

Condition

Eligibility

Eligible Ages
Between 18 Years and 80 Years
Eligible Genders
All
Accepts Healthy Volunteers
No

Inclusion Criteria

  1. Age is ≥ 18 and ≤ 80 years 2. Has a single unruptured target intracranial aneurysm (IA) with the following characteristics: 1. Is located on the internal carotid artery (ICA) or its branches. 2. Has a neck ≥ 4 mm, dome to neck ratio ≤ 2.0, or no discernible neck 3. Aneurysm size is ≤ 12 mm (saccular or fusiform configuration) 3. Has a parent vessel diameter ≥ 1.75 mm and ≤ 5.0 mm at both the proximal and distal segments where the implant will be placed 4. Has multiple increased risk factors for intracranial (IA) aneurysm rupture, including but not limited to, aneurysm morphology, smoking, hypertension, diabetes, age, prior and/or family history of rupture, and/or history of subarachnoid hemorrhage that may result in a benefit risk profile of endovascular treatment that outweighs the risks of intracranial aneurysm rupture during the subject's expected lifetime if left untreated.

Exclusion Criteria

  1. Has an extradural target aneurysm 2. Has a target aneurysm in the posterior circulation 3. Perforator or branch vessel, inclusive of the posterior communicating artery, arises from the target aneurysm body or neck (branches or arteries must arise or connect from the parent vessel separate from the aneurysm or neck to not be excluded from study) 4. Has a true bifurcation aneurysm, defined as an aneurysm (saccular or non-saccular) located at a point of vessel bifurcation 5. Target aneurysm is unsuitable for flow diverter treatment 6. Has vessel characteristics, such as severe tortuosity (cICA Type IV), stenosis (>70%), or morphology that would preclude safe endovascular access to the target aneurysm necessary for treatment with the study device 7. Received previous treatment of the target aneurysm or parent artery where it would interfere with the placement or proper apposition of the device 8. Has a medical contraindication to study or procedure related antiplatelet medications (aspirin, clopidogrel/Plavix, ticagrelor, and heparin), local or general anesthesia, or life-threatening allergy to contrast dye 9. Has a known severe allergy to nickel, chromium cobalt, tungsten or platinum. 10. Modified Rankin Score (mRS) assessment is ≥ 3 at preprocedure exam 11. Presence of unstable neurological deficit (i.e., worsening of clinical condition in the last 30 days) 12. Subarachnoid hemorrhage occurred within 30 days prior to enrollment 13. Major surgery (including previous intracranial implant) occurred within previous 30 days or is planned in the next 120 days after enrollment date 14. Has more than one IA that requires treatment within 12 months 15. Received previous intracranial implant associated with the symptomatic or vascular distribution within the past 12 weeks prior to treatment date 16. Chronic anticoagulation therapy is ongoing or known coagulopathy exists 17. Has other known serious concurrent medical conditions such as heart disease (e.g., unstable atrial fibrillation [with or without pacemaker], recent myocardial infarction [< 12 weeks ago], symptomatic congestive heart failure, or carotid stenosis), kidney failure [>2.0mg/dl serum creatinine], pulmonary disease, uncontrolled diabetes, progressive neurologic disorders, terminal cancer, vasculitis, high risk of ischemic stroke or recent stroke 18. Has acute life-threatening illness other than the neurological disease (e.g., acute kidney or heart failure) to be treated in this trial 19. Life expectancy is less than 5 years due to other illness or condition (in addition to an intracranial aneurysm) 20. Unable to complete study follow up due to dementia or psychiatric problem, substance abuse, or history of noncompliance with medical advice 21. Pregnancy at time of enrollment 22. Presence of intracranial mass (tumor, except meningioma, abscess, or other infection), non-treated arteriovenous malformation (AVM) in the territory of the target aneurysm 23. Evidence of active infection at the time of treatment 24. Enrollment in another trial involving an investigational product that could confound the outcomes of this trial

Study Design

Phase
N/A
Study Type
Interventional
Allocation
N/A
Intervention Model
Single Group Assignment
Primary Purpose
Treatment
Masking
None (Open Label)

Arm Groups

ArmDescriptionAssigned Intervention
Experimental
Surpass Evolve Flow Diverter System
This is a prospective single arm study in which all subjects who present for flow diverter implantation, provide informed consent, and meet inclusion/exclusion criteria may receive treatment (Surpass Evolve Flow Diverter).
  • Device: Surpass Evolve Flow Diverter System
    The Surpass Evolve Flow Diverter System is indicated for the endovascular treatment of adults (age 18 or above) with unruptured saccular wide-neck or fusiform intracranial aneurysms ≤12 mm.

More Details

Status
Active, not recruiting
Sponsor
Stryker Neurovascular

Study Contact

Detailed Description

The Surpass Evolve Flow Diverter System is indicated for the endovascular treatment of adults (age 18 or above) with unruptured saccular wide-neck or fusiform intracranial aneurysms ≤ 12 mm for treatment in vessel diameters between 1.75-5.0mm.

Notice

Study information shown on this site is derived from ClinicalTrials.gov (a public registry operated by the National Institutes of Health). The listing of studies provided is not certain to be all studies for which you might be eligible. Furthermore, study eligibility requirements can be difficult to understand and may change over time, so it is wise to speak with your medical care provider and individual research study teams when making decisions related to participation.